EICR in Poole

An Electrical Installation Condition Report (EICR) is a formal document produced after a qualified electrician has assessed the fixed electrical installation in a property.

Call us on 01202 000000 (placeholder - not in service)

EICR

An Electrical Installation Condition Report (EICR) is a formal document produced after a qualified electrician has assessed the fixed electrical installation in a property. The assessment checks that wiring, distribution boards, earthing and bonding, protective devices and fixed electrical equipment are in a satisfactory condition and in compliance with current wiring standards.

An EICR assigns observation codes to any issues found. A C1 code indicates a condition that presents immediate danger; C2 indicates a potentially dangerous condition; and C3 indicates that improvement is recommended but the installation is not currently dangerous.

C1 and C2 observations require remedial action. FI means further investigation is required and must also be addressed; C3 is an improvement recommendation.

Follow the report and any specified deadlines rather than treating an installation with unresolved investigation as accepted. England rented-sector rules require inspection and testing at least every five years, or sooner if the report specifies.

A valid existing report can cover a new tenancy. Give the report to existing tenants within 28 days, new tenants before occupation, and prospective tenants within 28 days of a request.

The rules were extended to the social rented sector in 2025; check the current sector-specific requirements. Homeowners are not subject to the same obligation but may want an EICR when purchasing a property, when an installation has not been checked for many years, or when significant renovation work is planned.

The assessment involves a visual inspection of accessible parts of the installation and a series of electrical tests on circuits, protective devices, earthing and bonding. The electrician checks that residual current devices (RCDs) operate correctly, that circuit protection is appropriate, and that wiring is adequately protected from damage.

If the EICR identifies issues, the engineer can advise on the remedial work needed to bring the installation to a satisfactory standard, and this work can be arranged through the same service.

Signs that an EICR may be overdue

⚠️

No record of a previous electrical assessment

If you cannot locate any documentation showing when the installation was last formally assessed, arranging an EICR is a sensible step, particularly in properties that have not had significant electrical work done in many years.

⚠️

Persistent circuit trips or non-functioning outlets

Recurring circuit breaker trips, outlets that do not work, or flickering lights can point to underlying faults in the installation. A formal assessment would identify these issues and assign them an observation code for severity.

⚠️

Visible signs of deterioration

Cracked or discoloured sockets, evidence of heat damage around outlets, or visible older-style wiring such as rubber-sheathed cables suggest the installation may not meet current standards and should be assessed by a qualified electrician.

How the EICR process works

1

Submit an enquiry

Provide details about the property, whether it is owner-occupied or rented, when it was last electrically assessed if known, and any issues you are aware of. This helps arrange the most appropriate engineer for the job.

2

On-site assessment

The electrician carries out a visual inspection of the fixed installation and tests circuits, protective devices, earthing and bonding. All accessible parts of the installation are checked against the current wiring standard.

3

Report and next steps

The completed EICR is issued with observation codes for any issues found. If the report is unsatisfactory, the engineer advises on the remedial work required and this can be arranged through the same service.

FAQs About EICR

How often is an EICR required for a rented property in England?
England rented-sector rules require inspection and testing at least every five years, or sooner if the report specifies. A valid existing report can cover a new tenancy. Supply it to existing tenants within 28 days, new tenants before occupation and prospective tenants within 28 days of a request. The rules now also cover the social rented sector; check the current requirements for the tenancy.
What happens if an EICR comes back as unsatisfactory?
C1 requires immediate action to remove danger; C2 requires remedial work, and FI requires further investigation. Under the rented-sector rules, landlords must complete required remedial or investigative work within 28 days or the shorter period specified in the report, and retain the required written confirmation. Other owners should follow the electrician's safety advice and the report rather than assume the landlord deadline is a general grace period.
How long does an EICR assessment typically take?
The time required depends on the size of the property and the complexity of the installation. A typical domestic property may take two to four hours. Larger properties or those with older, more complex installations may take longer.
Does an EICR cover appliances and portable equipment?
No. An EICR covers the fixed electrical installation, which includes wiring, the consumer unit, sockets, switches, lighting points and earthing arrangements. It does not cover portable appliances or white goods. Portable appliance testing (PAT) is a separate process.
How should I prepare for an EICR visit?
Ensure the electrician can access the consumer unit, all sockets and light switches, and any loft or underfloor space that contains wiring. Make a note of any known issues with the installation, such as circuits that trip frequently or outlets that do not work, and share these with the engineer at the start of the visit.
Can I arrange an EICR when buying a property?
Yes. Having an EICR carried out on a property you are considering purchasing gives you a clearer picture of the condition of the electrical installation before you commit. Any issues found can inform negotiations or help you budget accurately for any remedial work that may be needed.

More Electrical Inspections & Testing services

EICR CostPAT TestingLandlord Electrical Certificate

Other services in Poole

🏠 Fuse Board / Consumer Unit Replacement ⚡ Rewiring 🔌 Lighting & Sockets 🏠 EV Charger Installation ⚡ Emergency Electrician

Related guides

Understanding electrical inspections in Poole

Areas

Contact

Describe the problem and provide your contact details. Sending an enquiry does not confirm a booking.

01202 000000 (placeholder - not in service)
Use the enquiry form; the telephone number is a placeholder.
Service area: Poole.